NOTE: The selected cassette is indicated in a text box at top of screen.
1 Bill Width - This option enables you to enter the width of the item in the selected cassette. The information is stored in the cassette.
When 1 is pressed, enter the width of the notes loaded in the cassettes (in millimeters) in the data entry dialog screen.
Press ENTER when complete.
2 Bill Length - This option enables you to enter the length of the item in the selected cassette. The information is stored in the cassette.
When 2 is pressed, enter the length of the notes loaded in the cassettes (in millimeters) in the data entry dialog screen.
Press ENTER when complete.
3 Value - The table below provides a sample of value codes applicable to various common currency denominations.
Denomination  | 
			Value  | 
		
5  | 
			005  | 
		
10  | 
			010  | 
		
20  | 
			020  | 
		
50  | 
			050  | 
		
100  | 
			100  | 
		
When 3 is pressed, enter the Value in the data entry dialog screen.
Press ENTER when complete.
4 Variant - This is the single-character that represents the version of the note. The variant code should initially be set to one (1). If a new version becomes available, contact Triton's Technical Support for an updated code.
When 4 is pressed, enter the variant parameter in the data entry dialog screen.
Press ENTER when complete.
5 Code - This code is a three letter description for the currency type, e.g., "USD" represents US Dollars.
Press 5 repeatedly to cycle through the available list of currency codes. The code that appears in the text box will be applied to the selected cassette.
NOTE: The Data String text box shows the complete currency data configuration value consisting of the code, value, and variant settings.
After all parameters have been configured, press ENTER. A prompt appears to remove and re-insert the selected cassette. This action completes the process of changing the value of the data stored in the cassette.