C0045ATMGurus_small.jpg

Description:

More notes than requested were dispensed.

(During dispensing)

Resolution:

  1. Audit cassette note count with settlement.

  2. Check/clean CS13 sensor.

  3. Check functionality of sensor (CS13) in Diagnostics (Operator Function menu > Diagnostics > Sensors).

  4. Perform test dispense in diagnostics.

Models: